WARM BLOOD SAVES LIVES
Hypothermia is a condition where the body’s own heat production can’t match the heat loss to the environment resulting in a lowered body core temperature. Trauma patients do not die from hypothermia itself – they die of bleeding. Bleeding makes the body lose important red blood cells used to carry oxygen to the brain and other vital organs. Trauma patients with substantial bleeding are at risk of entering the deadly trauma triad of hypothermia, acidosis, and coagulopathy. This combination means that when the body core temperature drops, the acidity in the blood increases and the blood loses its ability to coagulate. Without coagulation, it is much more difficult to stop the bleeding and save the life of the patient.
Studies show that patients with admission temperatures less than 35 degrees C has significantly greater mortality.[1] This is a significant risk as studies also show that hypothermia is the most common cause of clotting disorder[2] and that approximately 57 % of trauma victims requiring immediate surgery become hypothermic in the period between injury and completion of the surgery.[3]
The American Center for Army Lessons Learned (CALL) states that 80 % of trauma deaths in Iraq and Afghanistan had a body core temperature below 34 °C. The consequence of bleeding and a BCT below 34 °C is a 2.4-fold increase of blood loss, compared to having a normal body core temperature of 37 °C.[4]
Prevention of hypothermia and early intervention are very important when it comes to temperature control of the body – waiting until arrival at the hospital could be too late.
- Martin, R Shayn;et al. Injury-associated hypothermia: an analysis, Shock Vol 24(2), Aug. 2005, pp 114
- Kjærgård, B et. al, Behandling af den hypoterme patient, UGESKR LÆGER 170/23, 2008
- Betty J. Tsuei, Hypothermia in the trauma patient, Int. J. Care Injured (2004) 35, 7—15
- Jarvis – OEF OIF Casualty Statistics & Lessons Learned-REVISED 18 April 2005, C.A.L.L.
FAST & FOOLPROOF
In trauma situations, paramedics must act fast. Speed is crucial, requiring products to be very intuitive and easy to implement – so the vital treatments can start as soon as possible. With the °M Warmer transfusion with warm fluid can start in less than 30 seconds.
HIGH PERFORMANCE
The °M Warmer has not only extremely efficient warming capabilities (150 ml/min), fast warm-up time (less than 10 seconds) and the battery capacity to warm 1.5 litres of cold fluid (5°C), but is also designed to resist water, drop on hard surfaces and has a solid power plug that secures high performance in any emergency use.
PORTABLE DESIGN
The Power Pack and single use °M Warmer have a compact design and together weigh 760 grams making the °M Warmer System ideal for pre-hospital emergency teams. The single-use warmer’s small size (10cm x 5cm x 2cm) allows it to be attached to the patient close to the infusion site, using its integrated adhesive pad.

Súrefnismettunarmælir - Onyx® Vantage 9590
PROACT Deluxe Emergency bakpoki
Nonin - Neonatal sensor
Segull fyrir stálflísatöku úr auga - með lykkju
WaterJel - Burn Jel - brunagel 50ml
Sjúkrakassi (tómur) - Flexibeauty
MDF®- Hlustunarpípa Dual Head - Black Out
LAP - Gult Low Profile Xenon ljós - 5W
TravelJohn - einnota þvagpokar fyrir bæði kyn
Blástursbelgur með möskum - einnota
Nonin Soft sensor medium
LED ljós 3PT 10-30V
Sjálflímandi plástur - 10 cm x 100 cm
Trömner hamar
Macintosh HPC barkablað - MAC 1
Ferno SCOOPEXL™ skröpur
STRÖLUX ljóskastarabar fyrir ökutæki - 204mm tvöfalt
Súrefnisgleraugu-Adult- 6 l/m
Infant sensor
LAP- LMB LED viðvörunarljós - Flexi DIN
Kokrenna 2 - 80 mm
Air-Qsp3G 0,0 Laryngeal Airways – Self-Pressurizing with Gastric Access
SAM Extrema spelka
Kokrenna 000 - 40 mm
Nonin Flex sensor - fullorðins
LAP LED ljósviti - 3ja punkta - 10-110V
StatPacks Quicklook AED sjúkrabakpoki
NOSA menthol plugs 7-pack
Honeywell Granular Carbon Filter fyrir HPA710 lofthreinsivél
SAM Pelvic Sling standard
Æðatöng Mosquito 12,5 bogin
E-VEST’S EMT vesti rautt
Ljósabogi Clear lens gulur Single point
Macintosh barkablað - HPC MAC3
Nonin 7500 súrefnismettunarmælir 




